Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Generation of a zone chirp in uniform Bragg grating as a way of obtaining double functionality of a sensor

Tytuł:
Generation of a zone chirp in uniform Bragg grating as a way of obtaining double functionality of a sensor
Autorzy:
Kisała, P.
Powiązania:
https://bibliotekanauki.pl/articles/221165.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
fibre Bragg gratings
strain and temperature sensor
temperature-insensitive measurement method
Źródło:
Metrology and Measurement Systems; 2012, 19, 4; 727-738
0860-8229
Język:
polski
Prawa:
CC BY-NC-ND: Creative Commons Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 PL
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
This paper presents a method of using a sensor with uniform Bragg grating with appropriately generated zone chirp. The presented method can be used for measuring two physical quantities, namely strain and temperature. By providing the same temperature sensitivity and different sensitivity to strain of two parts of a sensor, and experimental measurement of qualities of the proposed system and its calibration (experimental determination of sensitivity), verification of the results obtained from laboratory tests and the possibility of its practical implementation has been confirmed. The sensor grating was placed in such a way that its half was in the zone of a variable value of axial strain caused by changes of the cross-section of the sample. The other half, however, was in the zone of a constant cross-section of the sample and of constant value of strain, caused by the force stretching the sample. The obtained errors of non-linearity of processing characteristics for measuring strain and temperature of the proposed system were 2.7% and 1.5% respectively, while coefficients of sensitivity to strain and temperature were 0.77 x 10-6 m/e and 4.13 x 10-12 m/K respectively. The maximum differences between the values obtained from the indirect measurement and the set values were 110 žε for strain and 3.8°C for temperature, for a strain of 2500 žε and a temperature of 40°C.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies