Tytuł pozycji:

Testing and modeling of constant magnetic field cylindrical magnetoelectric sensors output characteristics

Tytuł:
Testing and modeling of constant magnetic field cylindrical magnetoelectric sensors output characteristics
Autorzy:
Kuczynski, Karol
Bilski, Piotr
Bilski, Adrian
Szymanski, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/2204515.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
magnetoelectric effect
magnetostriction
magnetometers
amorphous magnetic materials
piezoelectric materials
efekt magnetoelektryczny
magnetostrykcja
magnetometry
amorficzne materiały magnetyczne
materiały piezoelektryczne
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2023, 71, 1; art. no. e144583
0239-7528
Język:
angielski
Prawa:
CC BY: Creative Commons Uznanie autorstwa 4.0
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
The paper presents the novel concept of the magnetoelectric sensor constructed using the amorphous glass ribbon. Its output characteristics (voltage pattern), conditions of work and experimental results are presented. The novel construction allows for minimizing the demagnetizing field in the core of the sensor and linearization of the characteristics between the magnetic field and obtained voltage. Conducted experiments were aimed at determining the sensor operation in the presence of the constant magnetic field (HDC). The main concern of the tests was to verify the linear dependency between the HDC value and the amplitude of the output voltage. Next, the computer model representing the sensor behavior in the constant magnetic field is described. The model implements the parameter identification task based on the regression algorithms. The presented work shows that the proposed device can be used to measure the weak magnetic field and the dependency between the output signal amplitudes and the constant component in the measured magnetic field is approximately linear. This enables measurements of even weak fields.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies