Personal formaldehyde exposure level in the gross anatomy dissecting room at college of medicine King Saud University Riyadh

Tytuł:
Personal formaldehyde exposure level in the gross anatomy dissecting room at college of medicine King Saud University Riyadh
Autorzy:
Vohra, Muhammad S.
Powiązania:
https://bibliotekanauki.pl/articles/2185468.pdf
Data publikacji:
2011-03-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
formaldehyde
formalin
gross anatomy laboratory
dissection room
personal exposure level
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2011, 24, 1; 108-113
1232-1087
1896-494X
Język:
angielski
Prawa:
CC BY-NC: Creative Commons Uznanie autorstwa - Użycie niekomercyjne 3.0 PL
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
Introduction: This study was conducted to correlate the personal formaldehyde (FA) exposure levels of instructors and students with the indoor FA concentrations in gross anatomy laboratory at King Saud University. The personal FA levels of instructors and students are higher than the indoor FA concentration in the gross anatomy laboratory. Materials and Methods: The gross anatomy laboratory at college of medicine, King Saud University Riyadh, was observed for indoor FA concentration and the personal exposure levels of instructors and the medical students during the 4th, 10th and 14th weeks of the dissection sessions. All air samples were collected by the diffusive sampling device and analyzed by using high performance liquid chromatography (HPLC). Results: The personal exposure level of FA was higher than the indoor concentration, and the personal exposure levels of instructors were higher than that of the students. The concentration of FA was also higher in the center of the room than the corners and near the doors. Conclusion: Both the indoor FA concentrations and personal FA exposure levels are higher near the dissecting table than at locations away from it during the gross anatomy laboratory sessions. Thus, the instructors and students are exposed to the higher concentration of FA than the general population.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies