Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Charging and Discharging Strategies for Clustered Regional Energy Storage System

Tytuł:
Charging and Discharging Strategies for Clustered Regional Energy Storage System
Autorzy:
Li, Yang
Janik, Przemysław
Pfeiffer, Klaus
Schwarz, Harald
Powiązania:
https://bibliotekanauki.pl/articles/2175940.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
charging strategy
discharging strategy
energy storage system
energy-to-power ratio
fuzzy logic control
Źródło:
Power Electronics and Drives; 2022, 7, 42; 56--67
2451-0262
2543-4292
Język:
angielski
Prawa:
CC BY-NC-ND: Creative Commons Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
With the massive expansion of decentralised renewable energy in electricity grid networks, the power supply system has been changed from centralised to decentralised one and from directional to bi-directional one. However, due to the regional energy structure difference in the power imbalance between electricity generation and consumption is becoming more and more serious. A grid-scale energy storage system (ESS) can be one solution to balance the local difference. In this paper, two charging/discharging strategies for the grid-scale ESS were proposed to decide when and with how much power to charge/discharge the ESS. In order to realise the two strategies, this paper focuses on the application of fuzzy logic control system. The proposed strategies aim to reduce the peak power generation, consumption and the grid fluctuation. In particular, this paper analysis the ratio between energy-capacity and rated power of ESS. The performance of the proposed strategies is evaluated from two aspects, the normalised power of ESS itself and the influence on the power grid. Simulation studies were carried out on the rule-based control systems with different energy-to-power (e2p) ratios, and the results show that the proposed charging strategy with combination of extreme situation of power imbalance and the rest capacity of ESS provides a smooth load curve for the regional power grid system while the external power exchange is reduced effectively.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies