The paper presents issues associated with the impact of electromagnetic interference on track-side cabinets of a closed-circuit television system (CCTV) functioning in a railway transport environment. The measurements of an electromagnetic field emitted by a track-side CCTV cabinet were presented. Designs of this kind are operated in railway facilities; therefore, they should not disturb the functioning of other equipment, the rail traffic control systems, in particular (so-called inner compatibility). An analysis of the obtained results enabled developing a research model, and a further reliability and operational analysis, taking into account electromagnetic interference. This enabled determining a relationship allowing the determination of the probability of a track-side CCTV cabinet staying in a state of full ability. The presented discussions regarding a track-side CCTV cabinet, taking into account electromagnetic interference, allow for the numerical assessment of different types of solutions (technical and organizational), which can be implemented in order to mitigate the impact of electromagnetic interference on a system’s functioning.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies