A metallic film bolometer with heat capacity C is in contact with thermal bath and with crystalline specimen and is biased by a constant current I$\text{}_{b}$. The thermal contact of the bolometer is characterized by the thermal conductance G. The bolometer operates in the linear regime of dependence of resistance on temperature characterized by a constantα. Experiments which allow one to measureα, C, and G are proposed. The characteristic timeτ=C/G and characteristic current I$\text{}_{m}=\sqrt{\text{G/α}}$ affect the effective relaxation rateΛ of the bolometer resistance R$\text{}_{b}$(t). The knowledge of the power W(t) absorbed by detector allows one to calculate R$\text{}_{b}$(t). The inverse problem of calculation of W(t) from known R$\text{}_{b}$(t) is also solved. The suitable algorithms are proposed. Deconvoluted absorbed power is obtained for experiments performed on GaAs and compared with phonoconductivity signal of two-dimensional electron gas structure as well as with results of Monte Carlo computer experiments.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies