Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Efficiency of ventilated facades in terms of airflow in the air gap

Tytuł:
Efficiency of ventilated facades in terms of airflow in the air gap
Autorzy:
Schabowicz, Krzysztof
Zawiślak, Łukasz
Staniów, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/1845140.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ventilated facade
heat transfer
heat transmission
CFD
numerical simulation
energy efficient facade
Źródło:
Studia Geotechnica et Mechanica; 2021, 43, 3; 224-236
0137-6365
2083-831X
Język:
angielski
Prawa:
CC BY-NC-ND: Creative Commons Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
The gradual exploitation of the natural environment has forced most developed countries to promote ecological solutions and the development of sustainable construction. Ventilated facades perfectly match into this trend, and with their appropriate design, they bring real energy savings. This paper analyzes numerically the influence of the inflowing air, mimicking the wind, on the efficiency of heat removal from the ventilated space and heat transmission by thermal radiation and conduction through the consecutive layers of the external wall. For the purpose of comparison, two variants of ventilated facade were adopted: open and closed joints, at different wind speeds prevailing outside. The results obtained show that in windless weather, the ventilated facade with open joints shows higher heat removal efficiency and thus lower heat transmission to the building interior. At higher wind speeds of 5 m/s, the open-joint and closed-joint ventilated facades achieve similar heat transfer efficiency, and the prevailing temperature inside the building for the two technologies is almost identical. Subsequent increments of incoming wind on the building result in minimal differences in the heat transmission to the building interior, representing changes of about 0.1°C at increments of another 5 m/s of incoming wind. Conscious use of this facade technology, along with appropriate urban design of cities, can help reduce the energy needed to cool buildings during the summer period.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies