Test of Vibrations Influence on the Measurement Accuracy in the Precise Digital Leveller Trimble Dini 03 And Comparison of its Vibration Sensitivity with Leveller Ni 002
Test of Vibrations Influence on the Measurement Accuracy in the Precise Digital Leveller Trimble Dini 03 And Comparison of its Vibration Sensitivity with Leveller Ni 002
The article presents findings from research on the effect of vibrations on the accuracy of measurement with an automatic precise digital leveller. A special research station was created to induce vibrations on a leveller and to measure vibration parameters that affect staff reading. It contains description of discovered relationship between the vibration parameters and the mean error of a single height difference measurement. The range of frequencies for which the measurement was possible was estimated. The reliability of the measured values obtained under specific vibration conditions was also analysed. The results of current research were compared with similar studies on analogue leveller Ni 002. The conclusions described in this paper can be helpful in engineering measurements under adverse conditions of ambient vibrations.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies