Transmittance measurement of the in vivo human eye with a double-pass system

Tytuł:
Transmittance measurement of the in vivo human eye with a double-pass system
Autorzy:
Sánchez, Roberto
De Paul, Aníbal
Burgos-Fernández, Francisco
Vilaseca, Meritxell
Pujol, Jaume
Issolio, Luis
Powiązania:
https://bibliotekanauki.pl/articles/1835770.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
double-pass
transmittance
human eye
Źródło:
Optica Applicata; 2021, 51, 1; 1-21
0078-5466
1899-7015
Język:
angielski
Prawa:
CC BY: Creative Commons Uznanie autorstwa 4.0
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
Purpose: To develop a methodology based on a double-pass system to obtain information about the transmittance of ocular media. Methods: The procedure consists of recording double-pass images at different powers of a laser diode of 780 nm and determining the scattering in an area between 25–35 arcmin of each image. The scattering showed linear behavior in respect to the irradiance of the laser, and the slope of the linear fit was proportional to the transmittance squared of the media evaluated. An artificial eye with different filters was tested first. Then, fifteen subjects with clear ocular media were divided into two groups: ten subjects classified by the iris color were recruited for the measurements of an ocular transmittance index and the estimation of the transmittance (group A), and another five subjects were selected for measurements with neutral filters (group B). Results: The measurements performed in group A presented a mean transmittance of 42.95%. No differences in the transmittance were found between subjects with different iris color (p = 0.154). Measurements in group B showed a good correlation (r = 0.959, p < 0.001) between the expected and the measured value for the transmittance. Conclusion: We proposed and evaluated a method to determine the transmittance of the eye in vivo using the double-pass system.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies