Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Metrological aspects of international intercomparison of passive radon detectors under field conditions in Marie Curie’s tunnel in Lurisia

Tytuł:
Metrological aspects of international intercomparison of passive radon detectors under field conditions in Marie Curie’s tunnel in Lurisia
Autorzy:
Cardellini, F.
Chiaberto, E.
Garlati, L.
Giuffrida, D.
Leonardi, F.
Magnoni, M.
Minchillo, G.
Prandstatter, A.
Serena, E.
Trevisi, R.
Tripodi, R.
Veschetti, M.
Powiązania:
https://bibliotekanauki.pl/articles/146585.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
active monitors
calibration
intercomparison
radon
Źródło:
Nukleonika; 2016, 61, 3; 257-261
0029-5922
1508-5791
Język:
angielski
Prawa:
Wszystkie prawa zastrzeżone. Swoboda użytkownika ograniczona do ustawowego zakresu dozwolonego użytku
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
In 2014, an intercomparison exercise of passive radon detectors under field conditions in the Marie Curie’s tunnel belonging to the Lurisia spas complex (Lurisia, Piedmont, Italy) has been held. Radon activity concentration in the tunnel was measured with six radon active monitors, previously calibrated at ENEA-INMRI facilities. In the present paper, a synthesis of the metrological aspects of the intercomparison is given. Indeed particular attention was paid to metrological characterization of radon monitors and their response upon ambient conditions. Correction factors have been defined to be applied when measurements are performed in severe environmental conditions. In particular, it has been found that monitors are particularly sensitive to the effect of air density: the AlphaGUARD (AG-SAPHYMO, GmbH) effi ciency decreases with the air density, while for the MR1 PLUS (Tesys, Italy), the opposite applies. When the reference monitors were placed into the Marie Curie’s tunnel, to the recorded average radon concentrations correction factors were applied. After the correction the difference between data coming from AG and MR1 PLUS is within the 1.7%.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies