The electric LSPMSM motor presented in the paper differs from standard
induction motor by rotor design. The insulated start-up winding is located in slots along
the rotor circumference. The winding ends are connected to the slip-rings. The rotor core
contains permanent magnets. The electromechanical characteristics for synchronous
operation were calculated, as were the start-up characteristics for operation with a shortcircuited
rotor winding. Two model motors were used for the calculations, the V-shaped
Permanent Magnet (VPM) – Fig. 3, and the Linear Permanent Magnet (IPM) – Fig. 4,
both rated at 14.5 kW. The advantages of the investigated motor are demonstrated in the
conclusions.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies