The paper presents a model for calculations of the temperature field in electric mine motors with a water cooled frame. That model was worked out with use of modified and improved thermal networks developed by the author for determining the temperature distributions in different types of ac machines. Thermal calculations for a selected type of 400 kW mining motor were performed with use of an original computer program. Their results were compared with those obtained from measurements. On the basis of the verified simulation results there was determined the influence of value changes of parameters characterising the work environment condition (ambient temperature, inlet temperature and cooling water discharge, degree of covering the casing with coal dust) on the mining motor thermal state.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies