This article describes the construction and principles of operation of a prototype energy-converting machine – a flow machine with pistons rotating in toroidal spaces. A comparative analysis of the results of simulation and experimental tests of fluid flow resistance in the presented prototype machine has been performed with the use of correlation and integral calculi. The article also presents a comparative analysis of the volumetric efficiency of the examined pump and of a Vogelsang pump with similar design and size. The present state of the research makes it possible draw conclusions about the high exploitation value of the proposed pump construction. For this displacement pump, performance increases along with rotational speed. However, it is different from other pumps by virtue of is simple and compact construction as well as greater capacity in relation to its size.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies