The article presents the results of experimental research and their comparison with CFD simulations for the original selective catalytic reduction system and WALKER replacement. The research was performed to develop the WALKER universal mixer. The SCR prototype without mixer and with the proposed mixer were tested and compared with the original VW part. The next step was reverse engineering, which consisted in scanning the tested parts with a laser and processing their point cloud in Leios2 program. Reverse engineering has allowed the reconstruction of 3D geometry of the tested parts in the Catia v5 program and then preparation their models for computational fluid dynamics. Numerical simulations were carried out in the Ansys Fluent program, thanks to which several quantities were determined e.g. uniformity index of gas flow through the monolith and coefficient of variation as a measure of mixing degree, which have a significant impact on the design of the mixer and the SCR system.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies