In this work a novel cyclonic-static micro bubble flotation column, using hydraulic separator with a conventional flotation column, was developed to separate oil droplets from emulsions. The system integrated the cyclonic and laminar flow coalescence with the pipe flow coalescence. The effect of process parameters such as circulation pressure, aeration rate, feed volumetric flow rate and viscosity of fluid on the efficiency of multi-flow pattern coalescence was investigated. The obtained results indicated that the coalescence efficiency increased with the circulation pressure, feed volumetric flow rate and aeration rate, whereas an increase in viscosity of fluid reduced the extent of coalescence. Besides, the size distribution of oil droplets in the cyclonic separator, pipe flow section and column flotation section were simulated in the flotation column using a special software. The simulation was compared with experimental data on the mean size of oil droplets.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies