Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

The mechanical aspect of titanium ion release after posterior instrumentation for early onset scoliosis

Tytuł:
The mechanical aspect of titanium ion release after posterior instrumentation for early onset scoliosis
Autorzy:
Danielewicz, Anna
Fatyga, Marek
Wójciak-Kosior, Magdalena
Sawicki, Jan
Różańska-Boczula, Monika
Sowa, Ireneusz
Latalski, Michał
Powiązania:
https://bibliotekanauki.pl/articles/109528.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
scoliosis
metal ions
implant
titanium
mineralization
Źródło:
Physicochemical Problems of Mineral Processing; 2019, 55, 6; 1442-1449
1643-1049
2084-4735
Język:
angielski
Prawa:
Wszystkie prawa zastrzeżone. Swoboda użytkownika ograniczona do ustawowego zakresu dozwolonego użytku
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
Surgical treatment of early onset scoliosis (EOS) is connected with the risk of early and late complications. The aim of the study is to assess influence of the rod fracture on the titanium ion release (TIR) in traditional growing rods instrumentation for EOS.56 patients treated surgically due to EOS were divided into three groups: 1) a control-patients newly operated due to scoliosis, patients treated with the traditional growing rod (TGR) and TGR who had rod fracture (FGR) and required a surgical revision. Titanium quantification in blood sample, skin fragment (CT –clean tissue) andmacrosco-pically contaminated tissue located near the implant (DT –dirty tissue) was performed using high-resolution emission spectrometry with excitation in inductively coupled plasma.The mean serum titanium level in control, TGR, and FGR groups were 1.93 ± 0.8, 5.61 ± 0.23, and 4.43 ± 0.1 μg/dm3, respectively. The mean CT titanium level in control, TGR, and FGR groups were 0.0045 ± 0.001, 0.0035 ± 0.001and 0.0065 ± 6.8 mg/g, respectively. The mean DT titanium level in TGR and FGR groups was 0.59 ± 0.02, and 1.022 ± 0.03 mg/g, respectively.Implant leadsto the TIR into tissues and blood. Increasing the number of anchors increases the titanium content inthe CT TGR group. Mechanical damage to the implant has no significant effect on the increase of TIR

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies