Occupational exposure caused by large broadcasting transmitters exceeds current reference levels. As it is common for different radio and TV transmitters to share the location, we analysed combined exposure on a 40-m high mast. The frequency modulation (FM) transmitter, located between the 10th and 30th metre, had the power of 25 kW, whereas an ultra-high frequency (UHF) transmitter of 5 kW occupied the top 8 m of the mast. Measured and calculated values of the electric field strength exceeded the reference levels up to 10
times; however, the results for the specific absorption rate (SAR) values show that the reference levels are very conservative for FM exposure, i.e., basic restrictions are not exceeded even when the reference levels are exceeded 10 times. However, for UHF exposure the reference levels are not conservative; they give a good prediction of real exposure.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies