The purpose of the present article was to determine odour emission rate from primary settling tanks after hermetisation. The paper presents the results of the research on odour emission from four settling tanks, covered with
self-supporting aluminium domes with a diameter of 52 meters, located on urban wastewater treatment plants, with
the planned flow capacity equal to 200 000 m3/day. Altogether, the olfactometry analysis of 189 samples of polluted
air pulled from the domes with the use of an air blower which has efficiency of 12 000 m3/h was conducted. The
results of odour concentration measurements were in a range of approximately 10 800 to 763 600 ouE/m3. Average
odour emission rate was equal to 102 ouE/(s · m2). The obtained value is much higher than the literature data,
available for non-hermetised settlers only. This rate enables better estimation of the odour stream that has to be
deodorised after sealing the settling tanks.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies