The paper summarises the results of laboratory testing of an energy harvesting vibration reduction system based on a magnetorheological
(MR) damper whose control circuit incorporates a battery of bipolar electrolytic capacitors (current cut-off circuit). It is designed
to reduce the undesired effects in vibration reduction systems of this type, associated with the increasing amplitude of the sprung
mass vibration under the excitation inputs whose frequency should exceed the resonance frequency of the entire system. Results have
demonstrated that incorporating a current cut-off circuit results in a significant decrease of sprung mass vibration amplitudes when the frequency
of acting excitation inputs is higher than the resonance frequency.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies