Understanding the factors that influence the quality of
unmanned aerial vehicle
(UAV)-based products is
a scientifically ongoing and relevant topic. Our research focused on the impact of the
interior orientation
parameters
(IOPs) on the positional accuracy of points in a calibration field, identified and measured in an
orthophoto and a point cloud. We established a calibration field consisting of 20 materialized points and
10 detailed points measured with high accuracy. Surveying missions with a fixed-wing UAV were carried
out in three series. Several image blocks that differed in flight direction (along, across), flight altitude
(70 m, 120 m), and IOPs (known or unknown values in the image-block adjustment) were composed. The
analysis of the various scenarios indicated that fixed IOPs, computed from a good geometric composition,
can especially improve vertical accuracy in comparison with self-calibration; an image block composed
from two perpendicular flight directions can yield better results than an image block composed from a single
flight direction.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies