Masonry arches are regularly used in construction. The main purpose of this work was to perform numerical calculations using the Finite Element Method to estimate the load capacity of the designed masonry arch and to identify optimal locations for sensors on a real structure to aid advanced structural analysis. The model was implemented in two computer programs - Autodesk Robot and DIANA, and the results were compared. The arch was analysed statically and dynamically in the elastic range. A preliminary 2D static analysis was performed in Autodesk Robot, while in DIANA both flat and spatial models were analysed using both static and dynamic analysis. Numerical estimation of the load capacity of the masonry structure gave the opportunity to show the basic failure mechanisms together with the character of the stress distribution as well as the eigenfrequencies and eigenmodes. Satisfactory results were obtained, after a review of the literature.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies