Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Design of PI sliding mode control for Zeta DC-DC converter in PV system

Tytuł:
Design of PI sliding mode control for Zeta DC-DC converter in PV system
Autorzy:
Hasanah, Rini Nur
Ardhenta, Lunde
Nurwati, Tri
Setyawati, Onny
Sawitri, Dian Retno
Suyono, Hadi
Taufik, Taufik
Powiązania:
https://bibliotekanauki.pl/articles/2173675.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
photovoltaic
Zeta converter
sliding mode control
PI sliding surface
fotowoltaika
konwerter Zeta
sterowanie trybem przesuwnym
powierzchnia ślizgowa PI
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2022, 70, 3; art. no. e140952
0239-7528
Język:
angielski
Prawa:
CC BY-NC-ND: Creative Commons Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
Solar energy has become one of the most potential alternative energies in the world. To convert solar energy into electricity, a photovoltaic (PV) system can be utilized. However, the fluctuation of sunlight intensity throughout the day greatly affects the generated energy in the PV system. A battery may be beneficial to store the generated energy for later use. A DC–DC converter is commonly exploited to produce a constant output voltage during the battery charging process. A Zeta converter is a DC–DC converter which can be used to produce output values above or below the input voltage without changing the polarity. To deal with the inherent non-linearity and time-varying properties of the converter, in this paper the sliding mode control (SMC) is first analyzed and exploited before being integrated with a proportional-integral (PI) control to regulate the output voltage of the PV system. Disturbances are given in the form of changes in input voltage, reference voltage, and load. Voltage deviation and recovery time to reach a steady-state condition of the output voltage after disturbances are investigated and compared to the results using a proportional-integral-differential (PID) controller. The results show that the proposed control design performs faster than the compared PID control method.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies