The paper presents the author's own method for testing piezoelectric common rail fuel injectors, which for many years were considered non-repairable components. This was mainly due to the lack of availability of spare parts and dedicated measuring equipment, enabling full diagnostics under test bench conditions. As a result, their workshop and laboratory servicing was very limited, as effective disassembly concerned basically only the plunger and barrel assembly (needle with nozzle) for selected reference models. The situation has now improved to such an extent that an author’s own regeneration procedure has been proposed with the replacement of the most important controls and actuators. The tests were carried out on the example of Siemens VDO Continental PCR 2.3 fuel injectors from one engine, listing the most important stages of this process, including the correction of fuel dosage and returns.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies