Viscous damping is frequently used in the equation of motion to present the dissipation mechanism of a mechanical system. The orders of frequencies can be easily selected to determine viscous damping coefficients (VDCs) when the degree of freedom of the structure is low. For complex structures, difficulties in selecting the orders of reference frequencies to obtain reasonable VSCs are encountered. This paper mainly discusses the capability of the CWT method to select optimum frequencies of viscous damping formulation. The proposed procedure considers both the classical Rayleigh, modal and the proposed full model modal damping. The method is validated using a numerical time domain response of a two-stage gear system.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies