This paper presents an estimator-based speed sensorless field-oriented control (FOC) method for induction machines, where the state estimator is based on a self-contained, non-linear model. This model characterises both the electrical and the mechanical behaviours of the machine and describes them with seven state variables. The state variables are estimated from the measured stator currents and from the known stator voltages by using an estimator algorithm. An important aspect is that one of the state variables is the load torque and, hence, it is also estimated by the estimator. Using this feature, the applied estimator-based speed sensorless control algorithm may be operated adequately besides varying load torque. In this work, two different variants of the control algorithm are developed based on the extended and the unscented Kalman filters (EKF, UKF) as state estimators. The dynamic performance of these variants is tested and compared using experiments and simulations. Results show that the variants have comparable performance in general, but the UKF-based control provides better performance if a stochastically varying load disturbance is present.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies