The paper
presents results of analyses hydraulic conditions
of fl ow of weir in Jaktorów storied water for intake on fi shing pond in Agricultural
Institution the Experimental WULS. During
the fi eld inspection was made measurements:
construction elements of weir, cross section
on the length of storage in downstream and
upstream. Flow capacity calculation of weir
has been executed for different case of flow
transmission. Conditions for energy dissipation
were also estimated. Weir flow is limited
for capacity of downstream. Despite it
the weir is possibly conduct flood discharge
for storage water level without over flow
from channel. Due of to short stilling basin
it is made diffi cult safe transmission of flood
discharge.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies