Currently the CEN/TC250 is completing the development of a new (second) generation of Structural Eurocodes.
The checking of robustness remains one of the important stages in the design of structural systems. Recommended design
strategies for robustness checking are based on provisions given in actual EN 1991-1-7. A Non-linear pseudo-static analysis
is widely used by following reasons: a non-linear structural analysis based on more realistic constitutive relations for basic
variables makes possible a simulation of the real structural behaviour. Implementation of the non-linear pseudo-static
analysis for assessment of the structural system in accidental design situation requires an alternate approach to safety
format. The paper presents an innovative approach to safety format calibration for non-linear analysis of RC-structures
subjected to accidental loads.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies