Experimental study of CO, CxHy, NO, NOx and dust concentrations from a heat station supplied with rape cakes Badania stężeń CO, CxHy, NO, NOx i pyłu z kotłowni zasilanej makuchami rzepakowymi
CO, CxHy, NO, NOx and dust concentrations from a cherry stones supplied boiler with a nominal heat output of 15 kW were researched in a heat station. In the entrained flow furnace designed for firing wood pellets, melting and sintering ash phenomenon could not be successfully avoided. In comparison to wood pellet combustion, the observed boiler heat efficiency was lower. CO concentration was relatively high but did not exceed the permitted value. The impact of temperature in the combustion chamber and oxygen concentration on pollutant concentrations was determined. Pollutant emission indicators were estimated.
W kotłowni grzewczej badano ste)enia CO, CxHy, NO, NOx i pyłu z kotła o mocy nominalnej 15 kW, zasilanego makuchami rzepakowymi. W palenisku typu narzutowego do peletów drzewnych, mimo obni)enia temperatury, nie udało sie uniknac całkowicie zjawiska mieknienia i zlepiania sie popiołu. Uzyskano ni)sza ni) dla peletów drzewnych sprawnosc cieplna kotła oraz wy)sze ste)enie tlenku wegla, lecz poni)ej dopuszczalnej wartosci. Okreslono wpływ temperatury w komorze spalania i ste)enia tlenu na ste)enia zanieczyszczen. Oszacowano wskazniki emisji.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies
Informacja
SZANOWNI CZYTELNICY!
UPRZEJMIE INFORMUJEMY, ŻE BIBLIOTEKA FUNKCJONUJE W NASTĘPUJĄCYCH GODZINACH:
Wypożyczalnia i Czytelnia Główna: poniedziałek – piątek od 9.00 do 19.00