Cables may suffer severe damage in cable-stayed bridges, leading to cable relaxation and
tension loss. Such a damage effect merges in the sag augmentation or tension tightened by
the thermal effect. This paper is intended to investigate the static response of damaged
cables coupled with the thermal effect. With the introduction of three damage parameters
such as damage position, damage degree and damage range as well as temperature parameter,
the dimensionless governing equations for cables are derived and the numerical method is
employed to solve the nonlinear equations. The static behavior of damaged cables due to
the thermal coupling effect is analyzed, and the way to remove the thermal effect is given.
It shows that the aspect ratio is the major factor is the deflection of the mid-span and
horizontal force in the cable, whereas the angle inclination is the next important parameter.
Cables with the natural length close to the chord distance reveal the highest sensitivity to
temperature, whereas pre-tensioned and non-pre-tensioned cables are less sensitive to the
thermal effect. It further demonstrates that with more damage included, the sensitive scope
of the variation coefficient of the axial force with aspect ratio and temperature changes
dramatically.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies