Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Calculations of energy savings using lighting control systems

Tytuł:
Calculations of energy savings using lighting control systems
Autorzy:
Wiśniewski, A.
Powiązania:
https://bibliotekanauki.pl/articles/200771.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
light management systems
LED lamps
LED modules
LED luminaires
lighting technology
interior lighting
energy efficiency
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 4; 809-817
0239-7528
Język:
angielski
Prawa:
CC BY-NC-ND: Creative Commons Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
The development of technology and design of light management systems remains dynamic. Among all the benefits offered by these systems, the most valuable might definitely be the possibility of saving energy consumption. Knowing the value of energy savings is the key factor that users need to know before deciding to use a lighting management system (the type of light management system). For this purpose, it is useful to simulate the operation of the lighting control system, for example in the DIALux program. Such simulation helps evaluate potential savings in electricity consumption using the proposed lighting control system. In the DIALux program, it is possible to change the luminous flux value of luminaires. In such a case, it becomes possible to semi-simulate the light management system’s operation as we don’t receive actual information on reducing installed power of the lighting system during reduction of the luminous flux value of luminaires. This article shows what type of technical data are important to use for the DIALux program to properly and accurately simulate light management systems and to receive accurate data on energy saving. It also presents the results of photometrical and electric parameter measurements (Φ – luminous flux, P – power, PF – power factor, THDi – total harmonic distortion of current). The article discusses the power control characteristics obtained on the basis of these measurements and explores the source of differences between simulation of energy saving calculations and real measured energy savings. An existing lighting control system installed in an office reception area was used to compare calculations with the real value of energy consumption reduction. The impact of electronic power and control systems on electrical network parameters is also an important problem mentioned in this article. It also explores the effect of power regulation of LED luminaires and LED modules on the value of the power factor and total harmonic distortion (current) value (THDi).

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies