Comparison of near horizontal heterophoria tests in free space and with phoropter

Tytuł:
Comparison of near horizontal heterophoria tests in free space and with phoropter
Autorzy:
Perz-Juszczyszyn, Katarzyna
Feltzke, Monika
Dubas, Katarzyna
Maples, Willis Clem
Kołodziejczak, Barbara
Buczkowska, Hanna
Powiązania:
https://bibliotekanauki.pl/articles/1835794.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
Howell phoria card
near horizontal heterophoria
phoropter
Von Graefe test
Źródło:
Optica Applicata; 2021, 51, 2; 193-201
0078-5466
1899-7015
Język:
angielski
Prawa:
CC BY: Creative Commons Uznanie autorstwa 4.0
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
Background: Measurements of phoria at near are important elements of the optometric assessment of binocular vision. It is important to know if different methods of measuring a phoria are interchangeable. This study was designed to compare phoria measures using in-phoropter (von Graefe) and in free space methods (Howell card). Methods: The study was conducted with 70 pre-presbyopic subjects, aged 23–35 years. Both near the von Graefe and near Howell card horizontal dissociated phorias along and with gradient +1.00 D and –1.00 D phorias were measured for each technique. Results: The mean values of the near dissociated phoria, for both test conditions (von Graefe and Howell card) showed a slight deviation in the two measures with von Graefe measures being generally more exophoric. The mean value of the phoropter phoria was 1.97 ∆ base-in and in free space, the value was 0.9 ∆ base-in. The phoropter phoria with the +1.00 D gradient was 5.24 ∆ base-in, and in free space, 2.73 ∆ base-in. Measurements of the phorometric phoria with a gradient of –1.00 D gave a mean of 0.42 ∆ base-out and 0.94 ∆ base-out in free space. The near phoria measures were significantly different for the basic near measure (p = 0.01) and for the +1.00 D gradient (p = 0.000002) but not for the –1.00 D measure (p = 0.36). Conclusion: The results of the differences in the near horizontal phoria in free space and in- phoropter were significantly different for the basic measure and for the +1.00 D gradient. The findings between the two methods of testing should therefore not be treated as equivalent or convertible. Each test method should have separate means and ranges established.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies