Airborne acoustic properties of composite structural insulated panels CSIPs composed of fibre-
magnesium-cement facesheets and expanded polystyrene core were studied. The sound reduction ratings
were measured experimentally in an acoustic test laboratory composed of two reverberation chambers.
The numerical finite element (FEM) model of an acoustic laboratory available in ABAQUS was used and
verified with experimental results. Steady-state and transient FE analyses were performed. The 2D and
3D modelling FE results were compared. Different panel core modifications were numerically tested in
order to improve the airborne sound insulation of CSIPs.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies