This paper briefly describes direct power control methods for two- and threelevel AC/DC converters and their modified DPC 3H 2-? and the DPC 5H2-? algorithms. It also presents two new control methods DPC-3Am (direct power control 3 areas with modification) and the DPC-3L-3Am (direct power control 3 levels 3 areas with modification). The research results were used to compare the described methods. The comparison was based on an average value of switching frequency and current distortion coefficient. Experimental investigations into the methods have shown that the use of the modified DPC methods reduces the number of switchings by more than 70% compared with the standard DPC method.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies