The major reasons that cause the damage of damper bars in the leeward side
are found in this paper. It provides a route for the structure optimization design of
a hydro generator. Firstly, capacity of a 24 MW bulb tubular turbine generator is taken as
an example in this paper. The transient electromagnetic field model is established, and
the correctness of the model is verified by the comparison of experimental results and
simulation data. Secondly, when the generator is operated at rated condition, the eddy
current density distributions of damper bars are studied. And the asymmetric phenomenon
of the eddy current density on damper bars is discovered. The change laws of the
eddy currents in damper bars are determined through further analysis. Thirdly, through
the study of eddy current distributions under different conditions, it is confirmed that the
stator slots and armature reaction are the main factors to affect the asymmetric distribution
of the eddy current in damper bars. Finally, the studies of the magnetic density
distribution and theoretical analysis revealed the asymmetric distribution mechanism of
eddy current density.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies