Bezczujnikowa praca silnika z magnesami o polu osiowym w zakresie niskich prędkości wirowania Sensorless control of an axial flux permanent magnet motor at low speed
This paper shows a novel sensorless method of the rotor position detection of the permanent magnet motor. That method can operate at standstill, therefore initial position of the rotor can be detected. Moreover using a control system designed for presented method, low speed operations can be realized. Rotor position is obtained by applying short voltage pulse to the stator windings. Identification of the rotor position is provided by current responses analysis. Method is based on stator inductance changes in function of rotor poles position. This paper deals with theory confirmed by laboratory results on experimental set with 40 kVA / 16 poles / 3000 rpm Axial Flux Permanent Magnet Motor.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies